Skip to main content Skip to footer

Commercial Submittal Requirements

Commercial Requirements

CODES: 

  • 2018 International Building Code
  • 2018 International Mechanical Code
  • 2018 International Plumbing Code
  • 2018 International Fire Code
  • 2018 International Fuel Gas Code
  • 2018 International Existing Code
  • 2018 International Energy Conservation Code
  • 2018 International Property Maintenance Code
  • 2017 National Electrical Code
  • 2010 ADA Standards for Accessible Design

NOTE: Refer to Mohave County Building Ordinance 2021-03 for complete Amendments.

WIND SPEED: IBC 2018: 95 MPH Basic Wind Speed (Risk Category II)
(For site specific information please visit: https://hazards.atcouncil.org)

WIND EXPOSURE: C

SEISMIC ZONE: Category C

GROUND SNOW LOAD:

(DEPENDS ON ELEVATION) ZERO UP TO3,000’
5PSF FROM ABOVE 3,000’ TO 4,500’
10PSF FROM ABOVE 4,500’ TO 5,400’

PLAN REQUIREMENTS: 2 full sets of engineered building plans and calculations (1 set of plans and calculations must
be wet-stamped). Engineer must be registered in Arizona. All building plans must include a
code analysis listing the following information:

a. Code Block (codes the project has been designed to)
b. Scope of work
c. Occupancy
d. Height and area calculations
e. Type of construction
f. Occupant load
g. Fire suppression systems (if required)
h. Vicinity map
i. Site plan of the property
j. Owner information
k. Contractor information

GENERAL NOTES:

  • (Recommended) Pre-application meetings can be arranged through the Planning
    Department.
  • Steel buildings must be designed and inspected in accordance with the American Institute of
    Steel Construction (AISC 360).
  • Special inspection forms should be completed and included with permit application prior to submittal.

Updated 07/2021